Datos del producto

Especificación dominante

SOLENOID VALVE SV6~32, SSV, SV-G, NSV SERIES 
 

Technical data
Ambient temperature: -20 ~ 50
Liquid temperature: -25 ~ 120
Max. working pressure: 3MPa
Max. testing pressure: 3.5MPa
Available medium: R134aR22R407CR404A/507、air、water and oil
Rated power: 
A.C.: 24V,36V,110V,220V,380V 
D.C.: 12V,24V,110V,220V

Ordering
ExplanationValve codePort sizeConnection formNormal
opened
 code
Connection 
size
Rated 
power
ModelSV16WW-LK5/8AC220V
ExplanationSV: With 
diaphragms 

NSV: With 
pistons 

SSV: B-flow 
Port size
(mm)
Omit for flare 
SAE

W: Solder ODF 
G: Internal 
Thread 
410AOmit for 
normal 
closed 
valve

K: Normal 
opened 
valve
Connection 
Size omit for 
standard 
connection 
size
Rated 
powder

(V)
NotesThe model SV16WK-3/4-AC220V is an example in the table.
The order in the table is not suitable for SV1.6, SV2, SV3 series and type NSV6A.

Usage
1. The valve must install in horizontal pipe line under vertical position. The flow direction must meet 
the arrow direction in valve body.

2. The oil input voltage must meet rated input voltage showed on the label. Departure coil from valve 
when energized in coil is not permitted in order to avoid damage the coil.

3. According to valve with manual function, it must turn manual bar to open the valve before doing 
system air tightness in order to avoid to damage diaphram.

4. When brazing the valve with connect tube in system, follow points are very important:
a. Before brazing, coil must be departure and use wet fabric cover the valve body to avoid to 
damage valve part because of high temperature when brazing.

b. It must avoid the brazing flame face to valve body.
c. It is better to adopt low temperature type silver brazing bar.
5. According to valve with manual function. The manual bar must be turned to open the valve before 
doing system air tightness, in order to avoid to damage the diaphram.

6. Coil must be set to the body when the current on.
 





SOLENOID VALVES (WITH DIAPHRAGMS) SV SERIES
 

Introduction
SV series two ways normal closed solenoid 
valve with diaphragms can be widely used in 
refrigeration, pneumatic and hydraulic system, 
also in boiler and fire-fighting, etc.
Solenoid valves use full-closed magnetic coil 
and DIN international standard electric plug, so it 
is characterized by its good insulation, 
waterproof, moisture proof, anti-vibration and 
corrosion resistance.

Operating 
principle
While energized in coil, the electromagnetic power opens the small orifice. Then the pressure in 
upside of valve reduced, so the pressure difference between both side of diaphragm happen and lead 
to diaphragm lift to open the main orifice.

While de-energized in the coil, plug stem will drop and close the small orifice because of spring force 
and its weight. The flow media enters into upside of diaphrgm through throttle hole, then pressure in 
both side of diaphragm balances, then the diaphragm will drop and close the main orifice.
 

Type & data
Connection 
form
ModelConnection 
dimension
              
Kv 
value
          
(m
3/h)
Opening diff. 
pressure
(MPa)              
Dimension                       
(mm)
 (mm) (in.)MinMax
A.C.D.C.LengthWideHeight
Flare SAESV6Φ85/160.40.0052.11.7854597
SV8Φ103/81854597
SV10AΦ121/21.8854597
SV13AΦ165/83894597
SV16Φ193/44.511860120
SV19Φ227/8511860120
Solder ODFSV6WΦ85/160.41264597
Φ103/8
Φ121/2
SV8WΦ103/811264597
Φ121/2
SV10AWΦ121/21.81264597
Φ165/8
SV13AWΦ165/831504597
Φ193/4
Φ227/8
SV16WΦ193/44.519060120
Φ227/8
SV19WΦ227/8519060120
Φ25119060120
Φ281-1/821560120
SV25WΦ281-1/89.50.0324072120
Φ321-1/4
Φ351-3/8
SV32WΦ351-3/81526086130
Φ421-5/8
Φ481-7/8
Φ542-1/8
The Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa,ρ=1000kg/m3
Letters after the model: A means improved typr, W means solder ODF. K means normal opened 
valves.











SOLENOID VALVES (BI-FLOW) SSV SERIES

Introduction

 
SSV series teo-way bi-flow solenoid 
valves are mainly used for the defrosting 
of wind cooling heat pump refrigeration 
unit and the defrosting of supermarket 
refrigerators as well. 
The adoption of SSV series can reduce the 
amount of check valves and solenoid valves 
in the refrigeration system, which makes 
system pipeline designs more reasonable.

Function
When it is connected to the powder, the electromagnetic force of the pilot hole open, the upper chamber 
pressure decreased rapidly, on the low and high differential pressure is formed around the diaphragm, to 
promote the upward movement of the diaphragm, the valve opens, the two-way flow of the solenoid valve; 
energized, the spring forcepilot hole closed, when the inlet pressure is greater than the outlet pressure valve 
two-way closed, when the inlet pressure is less than the outlet pressure, the solenoid valve reverse 
circulation.
 

Type & data
Connection 
form
ModelConnection 
dimension
               
Kv 
value
          
(m
3/h)
Opening diff. 
pressure
                   
 (
MPa)
DIMENSION                        
 (mm)
 (mm) (in.)Min.Max.
A.C.D.C.LengthWideHeight
Flare 
SAE
SSV6Φ85/160.40.012.11.7854597
SSV8Φ103/81854597
SSV10AΦ121/21.8854597
SSV13AΦ165/83894597
SSV16Φ193/44.511860120
SSV19Φ227/8511860120
Solder ODFSSV6WΦ85/160.41264597
Φ103/8
Φ121/2
SSV8WΦ103/811264597
Φ121/2
SSV10AWΦ121/21.81264597
Φ165/8
SSV13AWΦ165/831504597
Φ193/4
Φ227/8
SSV16WΦ193/44.519060120
Φ227/8
SSV19WΦ227/8519060120
Φ251
Φ281-1/8
SSV25WΦ281-1/89.50.0324072120
Φ321-1/424072120
Φ351-3/8
SSV32WΦ351-3/81526086130
Φ421-5/826086130
Φ481-7/8
Φ542-1/8
The Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa,ρ=1000kg/m3
Letters after the model: A means improved typr, W means solder ODF. K means normal opened 
valves.










SOLENOID VALVES (WATER VALVES) SV-G SERIES
 

Introduction
SV-G series solenoid valve can be used as 
actor of automatic system in water supply 
system, fire control system, and water spray 
system in dirty proofing or agricultural. They 
also can be used for pneumatic hydraulic and 
food machine. 
Solenoid valves use full-closed magnetic 
coil and DIN international standard electric 
plug, so it is characterized by its good 
insulation, waterproof, moisture proof, 
anti-vibration and corrosion resistance.

Operating pricciple
While energized in coil, the electromagnetic power opens the small orifice. Then the pressure in upside of valve 
reduced, so the pressure difference between both side of diaphragm happen and lead to diaphragm lift to open 
the main ofifice.

While de-energized in the coil, plug stem will drop and close the small orifice because of spring force and its 
weight. The flow media enters into upside of diaphragm through throttle hole, then pressure in both side of 
diaphragm balances, then the diaphragm will drop and close the main orifice.
 

Type & data
Connection 
form
ModelConnection 
dimension

(mm)
Kv 
value
         
(m
3/h)
Opening diff. 
pressure
                    
 (
MPa)
Dimension                        
(mm)
Min.Max.
A.C.D.C.LengthWideHeight
Internal threadSV3/8GG3/810.0052.11.78045100
SV1/2GG1/21.86845100
SV3/4GG3/4512058119
The Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa, ρ=1000kg/m3
Letters after the model: G means internal thread.
Dimension (Unit:mm)
SV3/8G,SV1/2GSV3/4G


SOLENOID VALVES (WITH PISTONS) NSV6A
 

Introduction

NSV6A series two-way normal closed solenoid 
valves can operate under no pressure difference, 
which can be used for non-corrosive refrigerant in 
refrigeration system.

NSV6A series solenoid valves can install 
horizontally and vertically.

 

Technical data
Max. working pressure: 2.94Mpa   Max. testing pressure: 4.4MPa
Liquid temperature: -40~125    Ambient temperature: -30~50
Rated power: AC220V,AC110V

Type & data
Connection 
form
ModelConnection 
dimension

(in.)
Kv 
value

(m3/h)
Opening diff. pressure                     
(MPa)
Min.Max.
A.C.D.C.
Flare SAENSV6A3/80.6902.451.96
Solder ODFNSV6AW3/80.69
Kv value is the flow of water in m3/h at a pressure drop across valve of 0.1 Mpa, 
ρ=1000kg/m3

Dimension
(Unit:mm)







SOLENOID VALVES (DIRECT-ACTING) SV1.6, SV2, SV3 SERIES
 

Introduction


SV1.6, SV2, SV3 Direct-acting valves feature 
compact structure, rational design, easy 
installation and maintenance, and act repidly.
These series can be widely used in refrigeration, 
pneumatic and hydraulic systems. Solenoid 
valves use full-closed magnetic coil and DIN 
international standard electric plug, so it is 
characterized by its good insulation, waterproof, 
moisture proof, anti-vibration and corrosion 
resistance.
Operating 
principle
The pull of the solenoid coil opens the valve port directly by lifting the seat disc off the valve seat. 
While de-energized in the coil, plug stem will drop and close the valve port because of spring force 
and its weight.
 

Type & data
Connection 
form
ModelConnection 
dimension
Kv value         
(m
3/h)
Opening diff. 
pressure
                   
 (
MPa)
Dimension                         
(mm)
 (mm) (in.)Min.Max.
A.C.D.C.LengthWideHeight
Flare SAESV1.6Φ61/40.15032.6483355
SV2Φ61/40.16703075
SV3Φ61/40.232.11.7
Solder ODFSV1.6WΦ61/40.1532.6803355
SV2WΦ61/40.161153075
SV3WΦ61/40.232.11.7
Φ85/16
Φ103/8
Internal threadSV1.6A 3/80.1532.6303355
SV1.6B 1/8 (NPTF)
he Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa, ρ=1000kg/m3
Letter after the model: W means solder ODF, A & B means different valve bodies, K means normal 
opened valves.




DISCHARHGE SOLENOID VALVES SV-XZ SERIES
 

Introduction

SV-XZ series discharge solenoid valve, 
a kind of capacity requlators, are 
generally installed on the cylinder lid of 
compressors.

SV-XZ series discharge solenoid valves 
give automatic unloading adjustment of 
refrigeration compressor according to 
the capacity of evaporator. It can match 
the power of compressor with the 
requirement of refrigeration amount, and 
also save energy.

Type & data
ModelFigureInstallation 
size

(mm)
Installation 
hole size

(mm)
Max. opening 
diff. 
pressure
(Mpa)
Max. 
working 
pressure
(Mpa)
Max. 
medium 
temp.
()
Control 
Mode
SV2XZ2Rhombus652×Φ10.52.53150Direct-acting
Two-position 
& two-port

Normal 
closed
SV2XZ4Rhombus374×Φ7.2
SV2XZ5Square24×244×Φ4.3
SV2XZ5KSquare24×244×Φ4.3
SV2XZ8Rectangle64x324×Φ6.81.72.1100Two-position
 & three-port
Letter K after the model means normal opened solenoid valves. Contact with Shanghai Fengshen factory 
for special requirement.

 Volumn Table
          

Condiciones de pago T/T
Orden mínima N/A
Tiempo de entrega / Fecha de entrega 10Día(s)
Muestra Disponible S?Ask For Sample
Detalles de la entrega Efectivo de las válvulas de solenoide del amoníaco ASV16 en salida
Puerto del FOB Shanghai
Cargando Info Válvulas de solenoide del amoníaco ASV16 por el aire o por el mar
Información del embalaje Rectángulo del cartón de las válvulas de solenoide del amoníaco ASV16
Mercado Objetivo (s) Africa(except Middle East),  Central & Southern Asia,  Eastern Europe,  Hong Kong/ Macao/ Taiwan,  Japan & Korea,  Latin America,  Mainland China,  Middle East,  North America,  Northern Europe,  Oceania,  Southeast Asia,  Western & Southern Europe
Envíe su mensaje a este fabricante
Número de palabras: 0 personajes
-Mensaje debe contener 20 a 3000 caracteres.
-Nosotros sugerimos que usted pueda describir sus necesidades de productos y su perfil de la empresa
For better experience, explore the new online-showroom.

Fabricante

Shanghai Fengshen Refrigeration Controls Co., Ltd.

Ciudad: Shanghai

Telephone: (86)021-69176159

Contáctenos ahora